Related Experiment Video
Updated: Jan 20, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Defining the Dorsal STN Border Using 7.0-T MRI: A Comparison to Microelectrode Recordings and Lower Field Strength
Maarten Bot1, Okker Verhagen2, Matthan Caan3
1Department of Neurosurgery, Academic Medical Center, Amsterdam, The Netherlands, m.bot@amc.nl.
Background:
7.0-T T2-weighted MRI offers excellent visibility of the subthalamic nucleus (STN), which is used as a target for deep brain stimulation (DBS) in Parkinson's disease (PD). A comparison of 7.0-T MRI to microelectrode recordings (MER) for STN border identification has not been performed.
Objective:
To compare representation of STN borders on 7.0-T T2 MRI with the borders identified during MER in patients undergoing DBS for PD and to evaluate whether STN identification on 7.0-T T2 MRI leads to alterations in stereotactic target planning.
Design/Methods:
STN border identification was done using volumetric 7.0-T T2 MRI acquisitions. This was compared to the STN borders identified by MER. STN target planning was independently performed by 3 DBS surgeons on T2 imaging using 1.5-, 3.0-, and 7.0-T MRI.
Results:
A total of 102 microelectrode tracks were evaluated in 19 patients. Identification of the dorsal STN border was well feasible on 7-T T2, whereas the ventral STN was un-distinguishable from the substantia nigra. The dorsal STN border on MRI was located more dorsal than MER in 73% of trajectories. The average distance from MRI to MER border was 0.9 mm (range -4.4 to +3.5 mm). STN target planning showed high correspondence between the 3 field strengths.
Conclusion:
7.0-T T2 MRI offers the possibility of easy identification of the dorsal border of the STN. However, higher field strength MRI does not change the planning of the target. Compared to MER, the dorsal border on MRI was located more dorsal in the majority of cases, situating MER activity within STN representation.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength

