Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Simulation of a Right Anterior Thoracotomy Access for Aortic Valve Replacement Using a 3D Printed Model
Isaac Wamala1, Jan Brüning2, Johannes Dittmann3
1Department of Thoracic and Cardiovascular Surgery, German Heart Institute Berlin, Germany.
Objective:
The right anterior lateral thoracotomy (RALT) approach for aortic valve replacement provides excellent outcomes in expert hands while avoiding sternal disruption. It, however, remains a technically demanding niche operation. Instrument trajectories via this access are influenced by patient anatomy, the intercostal space chosen, and surgical retraction maneuvers.
Methods:
To simulate the typical surgical maneuvers, on an anatomically accurate model, and to measure the instrument trajectories, we generated a 3-dimensional (3D) printed model of the heart and chest cavity. A simulated approach to the base of the right coronary sinus via the medial-second intercostal, the lateral-second intercostal, or third intercostal space was made. Keeping the instrument in place, 3D scans of the models and geometrical measurements of the instrument trajectories were performed.
Results:
The 3D scans of the 3D printed model showed a high fidelity when compared to the original computed tomographic scan image geometry (mean deviation of 1.26 ± 1.27mm). The instrument intrathoracic distance was 75 mm via the medial-second, 115 mm via the lateral-second, and 80 mm via the third intercostal space. The 3D angulation of the instrument to the incision was 33.77o, 55.93o, and 38.4o respectively. The distance of the instrument to the lateral margin was 12, 26, and 5 mm respectively. The cranial margin of the incision was always a limiting margin for the instrument.
Conclusions:
Three-dimensional printing and 3D scanning facilitated a realistic simulation of the instrument trajectory during RALT approach. The lateral-second intercostal approach showed the most favorable approach angle and distance from the lateral margin, although it also had the longest intrathoracic distance.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...