Unique Challenges of Atopy Treatment in the Correctional Facility System: A Case Study

Justin Chin1, Koji Ota2, Lauren Strazzulla2

  • 1Family Medicine, Touro College of Osteopathic Medicine, New York, USA.

Cureus
|August 22, 2019
PubMed

Related Concept Videos

Other Unique Bacteria01:18

Other Unique Bacteria

Magnetic bacteria exhibit a directed movement called magnetotaxis, driven by structures called magnetosomes. These magnetosomes consist of chains of magnetic particles made of either magnetite (Fe₃O₄) or greigite (Fe₃S₄) and are organized in a linear conformation by a protein scaffold within invaginations of the cell membrane. The bacteria align along the north–south magnetic field lines, much like a compass needle. They are typically microaerophilic or anaerobic...
423
Second Uniqueness Theorem01:16

Second Uniqueness Theorem

Consider a region consisting of several individual conductors with a definite charge density in the region between these conductors. The second uniqueness theorem states that if the total charge on each conductor and the charge density in the in-between region are known, then the electric field can be uniquely determined.
In contrast, consider that the electric field is non-unique and apply Gauss's law in divergence form in the region between the conductors and the integral form to the surface...
2.6K
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
281
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
498
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
Case Studies01:22

Case Studies

There are many research methods available to psychologists in their efforts to understand, describe, and explain behavior and the cognitive and biological processes that underlie it.
13.3K