Related Experiment Video
Updated: Jan 20, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Photoreceptor evaluation after successful macular hole closure: an adaptive optics study
Ashish Markan1, Rohan Chawla2, Vinay Gupta1
1Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Objective:
To study photoreceptor changes after a successful macular hole surgery using adaptive optics.
Materials And Methods:
Three patients who underwent a successful macular hole surgery were studied. Cone density, spacing, and number of nearest neighbors were analyzed at 2° and 4° of eccentricity in all four quadrants using adaptive optics.
Results:
All three patients gained a visual acuity better than logMAR 0.477 (Snellen equivalent 6/18) at 6 months following successful macular hole surgery. Following successful closure of the macular hole, photoreceptors were appreciated at 2° and 4° of eccentricity from the center. However, as compared with the fellow normal eye, cell density was reduced significantly in the inferior (12,929.33 ± 2047.50 versus 23,839.67 ± 3711.16 cells/mm2 at 2°) and temporal quadrant (13,890 ± 3424.26 versus 22,578.67 ± 5651.34 cells/mm2 at 2°), and intercell spacing was increased significantly in inferior (9.6 ± 0.92 versus 7.14 ± 0.545 µm) and nasal quadrant (8.83 ± 0.39 versus 7.49 ± 0.42 µm). Number of nearest neighbors was unaffected after the hole closure.
Conclusion:
Postoperative recovery of vision after successful closure of the hole occurs because of the migration or shifting of cells from parafoveal retina toward the center. Cells nearest to the hole margin (at 2° eccentricity) appear to shift more as compared with cells which are further away.
More Related Videos
20:33A Case Series of Successful Abdominal Closure Utilizing a Novel Technique Combining a Mechanical Closure System with a Biologic Xenograft that Accelerates Wound Healing
Published on: July 4, 2019
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Photoreceptors and Plant Responses to Light
Ecological Succession
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Photoreceptors and Visual Pathways
Angle Closure Glaucoma: Treatment
Adaptability of Cytoskeletal Filaments