Differentiation of skin incision and laparoscopic trocar insertion via quantifying transient bradycardia measured by

Cheng-Hsi Chang1,2, Yue-Lin Fang3, Yu-Jung Wang1

  • 1Department of Anesthesiology, Shin Kong Wu Ho Su Memorial Hospital, Taipei, Taiwan.

Related Concept Videos

Electrocardiogram01:29

Electrocardiogram

An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
5.5K
Electrocardiogram Fundamentals01:28

Electrocardiogram Fundamentals

Introduction
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
1.4K
Quantifying Work02:30

Quantifying Work

As a system undergoes a change, its internal energy can change, and energy can be transferred from the system to the surroundings, or from the surroundings to the system.
24.1K
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
386
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
514
Quantifying Heat02:46

Quantifying Heat

Thermal Energy Microscopically, thermal energy is the kinetic energy associated with the random motion of atoms and molecules. Temperature is a quantitative measure of “hot” or “cold”, which depends on the amount of thermal energy. When the atoms and molecules in an object are moving or vibrating quickly, they have a higher average kinetic energy (KE) (or higher thermal energy), and the object is perceived as “hot”, or it is described as being at a higher temperature. When the...
61.8K