Accuracy of IOS in Full-Arch Dentate Patients Compared to CBCT Cast-Scanning. An In-Vivo Study
G Michelinakis1, D Apostolakis1, E Pavlakis1
1Private Dental Practice.
The European Journal of Prosthodontics and Restorative Dentistry
|August 22, 2019
Summary
The Trios intraoral scanner (IOS) demonstrated superior accuracy for full-arch digitization compared to cone beam computed tomography (CBCT) scanning of plaster models. Anterior teeth scans using IOS were also more precise than posterior teeth scans.
Area of Science:
- Dental Technology
- Digital Dentistry
- Oral Health
Background:
- Accurate digital impressions are crucial for modern restorative dentistry.
- Traditional PVS impressions and CBCT scanning have limitations in precision.
- Intraoral scanners (IOS) offer a potential alternative for digital impressioning.
Purpose of the Study:
- To compare the accuracy of full-arch digital impressions obtained by an intraoral scanner (IOS) versus cone beam computed tomography (CBCT) scanning of plaster models.
- To evaluate the accuracy of IOS for anterior and posterior teeth, as well as maxillary and mandibular arches.
Main Methods:
- Full-arch PVS impressions and IOS scans (Trios) were acquired from 20 patients.
- Plaster models from PVS impressions were scanned using CBCT and a desktop scanner (reference).
- STL files from IOS and CBCT were compared to the reference using 3D surface measurement software.
Main Results:
- The Trios IOS exhibited a significantly smaller median error (39μm) compared to CBCT (62μm).
- IOS accuracy was higher for anterior teeth (42±16μm) than posterior teeth (47±16μm).
- No significant accuracy differences were found between maxilla and mandible or left and right quadrants for IOS.
Conclusions:
- Full-arch digitization using the Trios IOS is significantly more accurate than CBCT scanning of plaster models.
- The Trios IOS provides statistically more accurate digitization for anterior teeth compared to posterior teeth.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
100.1K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
100.1K
The Arch of Aorta
1.6K
The coronary arteries, originating from the ascending aorta, bifurcate from two sinuses located within the ascending aorta. Positioned just above the aortic semilunar valve, these sinuses house essential aortic baroreceptors and chemoreceptors, crucial for maintaining cardiac function. The left coronary artery and the right coronary artery branch off from the left posterior and anterior aortic sinuses, respectively.
Encircling the heart, the coronary arteries form a ring-like structure before...
Encircling the heart, the coronary arteries form a ring-like structure before...
1.6K
Improving Translational Accuracy
14.1K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.1K
Improving Translational Accuracy
3.6K
3.6K
Accuracy and Precision
14.2K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. Highly accurate...
14.2K
Leaky Scanning
5.6K
During most eukaryotic translation processes, the small 40S ribosome subunit scans an mRNA from its 5' end until it encounters the first start AUG codon. The large 60S ribosomal subunit then joins the smaller one to initiate protein synthesis. The location of the translation initiation is largely determined by the nucleotides near the start codon as there may be multiple translation initiation sites present on the mRNA. Marilyn Kozak discovered that the sequence RCCAUGG (where R...
5.6K