Rapid Presumptive Identification of Bacillus anthracis Isolates Using the Tetracore RedLine Alert Test

Segaran P Pillai1, Kristin W Prentice2, Jason G Ramage3

  • 1Segaran P. Pillai, PhD, is Director, Office of Laboratory Science and Safety, FDA Office of the Commissioner, Department of Health and Human Services, Silver Spring, MD.

Health Security
|August 22, 2019
PubMed

Related Concept Videos

Methods of Classification and Identification01:28

Methods of Classification and Identification

Bacterial identification relies on a diverse array of techniques to classify and understand microorganisms, each tailored to uncover specific characteristics. Traditional morphological approaches, while still valuable, are limited for closely related or structurally simple organisms. Modern methods integrate biochemical, serological, genetic, and advanced molecular tools to achieve greater accuracy.Morphological and Biochemical TechniquesMorphological characteristics, such as cell shape and...
1.1K
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
459
RACE - Rapid Amplification of cDNA Ends02:35

RACE - Rapid Amplification of cDNA Ends

Rapid Amplification of cDNA Ends, or RACE, is one of the most effective methods to obtain a full-length cDNA from an mRNA sequence between a known internal region to the unknown sequence at the 5’ or 3’ end. The unknown region is cloned in the cDNA by a gene-specific primer that binds the known end, and a hybrid primer that attaches a predefined anchor sequence to the unknown end of the cDNA. The sequence in between is amplified by PCR with an anchor primer and a gene-specific...
7.2K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.1K
DNA Isolation01:24

DNA Isolation

DNA isolation protocols can be fast and straightforward or complex and time-consuming depending on the type and quality of DNA required for further processing. For example, plasmid DNA extraction is a bit more complicated than genomic DNA extraction because of the need for an appropriate lysis method to separate plasmid DNA from gDNA during isolation. However, for specific applications, such as long-range DNA sequencing that require a good yield of high- quality DNA samples, we need to follow...
44.7K
DNA Isolation01:34

DNA Isolation

DNA from cells is required for many biotechnology and research applications, such as molecular cloning. To remove and purify DNA from cells, researchers use various methods of DNA extraction. While the specifics of different protocols may vary, some general concepts underlie the process of DNA extraction.
199.1K