Related Experiment Video
Updated: Jan 20, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Femoral Cementation in Knee Arthroplasty-A Comparison of Three Cementing Techniques in a Sawbone Model Using the
M Schwarze1, M Schonhoff2, N A Beckmann1
1Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.
Abstract:
Femoral component loosening is a rare but severe complication in total knee arthroplasty. Former studies have repeatedly demonstrated radiolucent lines behind the ventral and dorsal anchoring shields of the femoral components, which has led us to investigate this matter further. Therefore, three different cementing techniques were tested in a group of nine Sawbone samples each. These differed in the amount of cement applied on the femoral component as well as in the pressure application. Computed tomography was performed to evaluate and classify the cement penetration into the bone adjacent to the prosthesis according to the zones defined by the Knee Society scoring system. The results show significantly deeper cement penetration in all zones when a pressurizer is used. In the other two groups, no significant difference in the dorsal bevel cement penetration was noted. Additionally, no difference in ventral and dorsal cement penetrations (Zones 1 and 4) was delineated. In contrast, there was a significant difference in both the ventral bevel (Zone 2) as well as the distal anchoring surface (Zones 5-7). The use of a pressurizer results in greater cement penetration into all anchoring areas. Completely covering the component back surface results in a significantly higher penetration, which is mainly due to differences in volume. These data show significantly improved cementation results when using a pressurizer. Whether this improves the biomechanical properties and ultimately the revision rate requires further investigation.
Related Concept Videos
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...

