Simultaneous Calibration of Odometry and Head-Eye Parameters for Mobile Robots with a Pan-Tilt Camera

Nachaya Chindakham1, Young-Yong Kim2, Alongkorn Pirayawaraporn1

  • 1Department of Control and Instrumentation Engineering; Kwangwoon University, Kwangwoon-ro 1-gil 60, Nowon-gu, Seoul 01890, Korea.

Summary

This study introduces a new simultaneous calibration method for robot navigation, accurately estimating both odometric and head-eye parameters for pan-tilt cameras. This approach reduces calibration time and improves precision for mobile robots.

Related Concept Videos

Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.3K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
690
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
448
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
4.5K
Wave Parameters01:10

Wave Parameters

The simplest mechanical waves are associated with simple harmonic motion and repeat themselves for several cycles. These simple harmonic waves can be modeled using a combination of sine and cosine functions. Consider a simplified surface water wave that moves across the water's surface. Unlike complex ocean waves, in surface water waves, water moves vertically, oscillating up and down, whereas the disturbance of the wave moves horizontally through the medium. If a seagull is floating on the...
9.1K
Muscles that Move the Head01:19

Muscles that Move the Head

The muscles that move the head are a dynamic and complex group of structures that work together to facilitate a wide range of head movements, including rotation, flexion, extension, and lateral bending.
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
5.6K