Introduction:
(1) To evaluate the influence of pedicle screw loosening on clinical outcomes; (2) to clarify the association between the pull-out length and screw loosening 1 year after surgery; and (3) to determine radiographically which screw parameters predominantly influence the pull-out resistance of screws.
Methods:
We analyzed 32 consecutive patients who underwent minimally invasive lumbar or thoracic spinal stabilization by intraoperative three-dimensional computed tomography (CT)-guided navigation without anterior reconstruction and were followed up for 1 year. The screw pull-out length was measured on axial CT images obtained both immediately after screw insertion and postoperatively. Loosening of screws and clinical outcomes were evaluated radiographically, clinically, and by CT 1 year after surgery.
Results:
There were no significant differences in the mean age, sex, bone mineral density, mean stabilized length, and smoking habits of patients with (+) or without (-) loosening. The Oswestry Disability Index and the lumbar visual analog scale 1 year after surgery were significantly higher in patients with loosening (+) than in those without (-). The overall pedicle screw pull-out rate was 16.2% (47/290) of screws and the overall screw loosening rate was 15.2% (44/290) of screws. Screws with loosening (+) had significantly lower (axial) trajectory angles and higher screw pull-out lengths than those without (-). Approximately 82% of loosened screws had been pulled out during rod connection.
Conclusions:
A lower axial trajectory and an increased screw pull-out length after rod reduction are crucial risk factors for screw loosening.
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Clinically Relevant Drug Product Specifications: Methods of Establishment
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Relative Risk