Related Experiment Video
Updated: Jan 20, 2026

Intraoperative Visualization of Subretinal Injection and Retinal Detachment in Rats
Published on: March 7, 2025
Perfluoro-n-octane-assisted mega Weiss-ring technique for posterior vitreous detachment induction in retinal
Naresh Babu1, Jayant Kumar1, Piyush Kohli1
1Vitreo-Retinal Services, Aravind Eye Hospital and Post Graduate Institute of Ophthalmology, Madurai, Tamil Nadu, India.
Abstract:
Induction of posterior vitreous detachment (PVD) is one of the most critical steps for the success of retinal detachment (RD) surgery. Failure to completely remove the vitreous can result in re-detachments. We describe a novel technique to induce PVD. After core vitrectomy, perfluorocarbon liquid (PFCL) is injected. The vitreous on the posterior pole is gently stroked, with a diamond-dusted membrane scraper, to create a defect in it. This defect is gradually enlarged to create a ring of rolled out vitreous. The entire vitreous is removed in form of a sheet by lifting the edges of the ring using an internal limiting membrane peeling forceps. PFCL naturally slides into the potential space, gradually extending the vitreous detachment peripherally. With this technique, the vitreous sheet in case of RD can easily, effectively and safely be removed with this technique.
Related Concept Videos
Induction
A...
Self-Inductance
Consider a circuit connected to an AC source. As the current varies with time, the magnetic flux through the circuit correspondingly changes. Faraday's law tells us that an emf would...
Cranial Bones: Superior and Posterior View
The frontal bone is the single bone that forms the forehead. At its anterior midline, between the eyebrows, there is a slight depression called the glabella. The frontal bone also forms the supraorbital margin of the orbit. Near the middle of this margin is the supraorbital foramen, the opening that provides passage for a sensory nerve to the forehead. The frontal bone is thickened just above each supraorbital margin,...
Inductive Reasoning
Inductive reasoning is common in descriptive science. A life scientist makes observations and records them. This data can be qualitative or...
Mutual Inductance
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...