Related Experiment Video
Updated: Jan 20, 2026

Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
H2-Based Electrochemical Biosensor with Pd Nanowires@ZIF-67 Molecular Sieve Bilayered Sensing Interface for
Shuzhen Lv1, Kangyao Zhang1, Ling Zhu1
1Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry , Fuzhou University , Fuzhou 350108 , People's Republic of China.
Abstract:
With the introduction of gas-based contactless electrochemical biosensors lies the prospects of separating the sensing interface from the bioassembly platform, enhancing stability, and exploring signal transduction mechanism, all intimately linking to development of immunoassay. Herein, we report on a H2-based electrochemical biosensor whose signals derived from the chemical signal transduction between a H2 and Pd nanowires@ZIF-67 (ZIF: Zeolitic Imidazolate Frameworks) bilayered sensing interface for immunoassay. Dendritic Pt nanoparticles (DPNs) conjugated on the detection antibody were introduced on the interface of a magnetic microsphere according to an immune sandwich assembly between the antigen and antibody. H2 as a bridge originates from DPNs catalyzing NH3BH3 and links biological signals to electrical signals by reacting with Pd nanowires. Nevertheless, the response of Pd nanowires being extremely effected by O2 in air due to the competitive adsorption on the surface of Pd nanostructures as well as the reaction between chemisorbed O (Pd-O) and adsorbed dihydrogen lead to a decrease in H absorption into PdH and poor sensing responses under low target concentration. Porous ZIF-67 (window aperture 0.331 nm) as a molecular sieve self-assembling on the surface of the Pd nanowires film could easily permeate H2 (kinetic diameter of 0.289 nm), while interferential O2 (kinetic diameter of 0.346 nm) has difficultly passing through the ZIF-67 layer to contact Pd nanowires and achieves a response of a lower concentration target as well as faster response rate. Under optimal conditions, H2-based electrochemical biosensors exhibit great response toward target alpha-fetoprotein (AFP) within a dynamic working range of 0.1-50 ng mL-1 at a detection limit of 0.04 ng mL-1. Our strategy provides a reusable sensing interface, high specificity, and acceptable accuracy for the immunoassay. In addition, it also expands a promising platform for application as a molecular sieve in electrochemical biosensors.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Sieve Analysis and Grading Curves
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Protein-protein Interfaces
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...

