Combined Thoracoscopic Surgical Stapling and Endobronchial Valve Placement For Lung Volume Reduction With Incomplete
Adnan Majid1, Fayez Kheir1,2, Daniel Alape1
1Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
Background:
In patients with severe emphysema and complete fissures, bronchoscopic lung volume reduction with valves reduces target lobe volume providing improvement in respiratory symptoms, lung function, quality of life, and exercise capacity. It is estimated that up to 88% of patients with emphysema have at least 1 incomplete interlobar fissure. The aim of this study was to evaluate the feasibility of creating a complete fissure with stapling via minimally invasive video-assisted thoracoscopic surgery (VATS) followed by bronchoscopic valve placement to induce lobar collapse in a swine model.
Methods:
Chest computed tomography (CT) scans were performed on 2 swine and at least 1 target incomplete fissure was identified. Both swine underwent VATS to complete the target fissure using a surgical stapler, followed by bronchoscopic placement of the Spiration endobronchial valves. A chest CT scan was performed immediately postprocedure. Follow-up bronchoscopy and CT scans were performed 2 weeks after the initial procedure prior to sacrifice.
Results:
Successful fissure completion was accomplished using VATS and confirmed at postmortem explanted lung gross examination. Flexible bronchoscopy 2 weeks following valve placement showed proper positioning of the valves. Effectiveness of combined procedures was confirmed by a chest CT scan that showed complete atelectasis of the target lobe at 2-week follow-up. There was no perioperative or postoperative morbidity or mortality.
Conclusion:
Combined minimally invasive VATS fissure stapling with bronchoscopic valve placement to induce lobar atelectasis appears safe and feasible in the swine model. Future research in humans using a combined procedure is needed to confirm safety and clinical efficacy.
More Related Videos
Related Concept Videos
Incomplete Dominance
Pilot and Numeric Relaying
Lung Capacity
Oxidation-Reduction Reactions
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...