Thoughts about high chlorine peaks in X-ray microanalysis.

C H Becker

    Experientia
    |August 15, 1979
    PubMed
    Summary

    High chloride (Cl) peaks in biological tissue analysis suggest this element originates from the tissue itself. This finding may enable rough regional estimations of chloride levels in biological samples.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography.

    European journal of radiology·2009
    Same author

    Laser desorption of DNA oligomers larger than one kilobase from cooled 4-nitrophenol.

    Rapid communications in mass spectrometry : RCM·1999
    Same author

    Single nucleotide polymorphism determination using primer extension and time-of-flight mass spectrometry.

    Electrophoresis·1999
    Same author

    Reliable genotyping of short tandem repeat loci without an allelic ladder using time-of-flight mass spectrometry.

    International journal of legal medicine·1999
    Same author

    Cryogenic frozen solution matrixes for analysis of DNA by time-of-flight mass spectrometry.

    Analytical chemistry·1997
    Same author

    High-throughput DNA analysis by time-of-flight mass spectrometry.

    Nature medicine·1997

    Area of Science:

    • Biomedical science
    • Analytical chemistry
    • Microscopy

    Background:

    • X-ray microanalysis frequently reveals high chloride peaks in biological tissues.
    • The source of this observed chloride is often unclear, potentially stemming from the sample or embedding medium.

    Purpose of the Study:

    • To investigate the origin of high chloride peaks observed during X-ray microanalysis of biological tissues.
    • To assess the feasibility of using chloride levels for regional estimations in biological samples.

    Main Methods:

    • X-ray microanalysis of biological tissues embedded in epoxy resin.
    • Comparison of chloride peak intensities within the tissue versus the surrounding epoxy environment.

    Main Results:

    • Consistently observed high chloride peaks in biological tissue samples.
    • Chloride peaks were significantly higher in the tissue compared to the epoxy embedding medium.
    • This suggests a substantial endogenous source of chloride within the biological tissue.

    Conclusions:

    • The majority of chloride detected in X-ray microanalysis of biological tissues originates from the tissue itself.
    • This endogenous origin of chloride opens possibilities for rough regional quantification of chloride levels in biological samples.