Design and Benchmark Testing for Open Architecture Reconfigurable Mobile Spirometer and Exhaled Breath Monitor with
Alexander G Fung1, Laren D Tan2, Theresa N Duong2
1Department of Mechanical and Aerospace Engineering, University of California, Davis, CA 95616, USA.
Abstract:
Portable and wearable medical instruments are poised to play an increasingly important role in health monitoring. Mobile spirometers are available commercially, and are used to monitor patients with advanced lung disease. However, these commercial monitors have a fixed product architecture determined by the manufacturer, and researchers cannot easily experiment with new configurations or add additional novel sensors over time. Spirometry combined with exhaled breath metabolite monitoring has the potential to transform healthcare and improve clinical management strategies. This research provides an updated design and benchmark testing for a flexible, portable, open access architecture to measure lung function, using common Arduino/Android microcontroller technologies. To demonstrate the feasibility and the proof-of-concept of this easily-adaptable platform technology, we had 43 subjects (healthy, and those with lung diseases) perform three spirometry maneuvers using our reconfigurable device and an office-based commercial spirometer. We found that our system compared favorably with the traditional spirometer, with high accuracy and agreement for forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC), and gas measurements were feasible. This provides an adaptable/reconfigurable open access "personalized medicine" platform for researchers and patients, and new chemical sensors and other modular instrumentation can extend the flexibility of the device in the future.
Related Concept Videos
Breathing
Design Example: Setting a Curve Using Design Data
Pulmonary Cycle: Exhalation
Group Design
Statistical Inference Techniques in Hypothesis Testing: Parametric Versus Nonparametric Data
Parametric statistics, as the name suggests, assumes that data follow a specific distribution, often a normal distribution. This assumption enables robust hypothesis testing and estimation. Parametric methods, like the Student's t-test or Goodness-of-fit test, are frequently employed in biostatistics due to their robustness. For instance,...
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration: