Related Experiment Video
Updated: Jan 20, 2026

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher
Published on: February 23, 2018
Absorption and Extraction of Inflammatory Mediators From Contact Lens Materials
Cecilia Chao1, Kathryn Richdale, Mark Willcox
1State University of New York College of Optometry (C.C., K.R.), New York, NY; School of Optometry and Vision Science (C.C., M.W.), University of New South Wales, Sydney, NSW, Australia; Center for Translational Ocular Immunology (C.C.), Tufts Medical Center, Boston, MA; and University of Houston College of Optometry (K.R.), Houston, TX.
Objectives:
This report aimed to explore whether certain inflammatory mediators were absorbed, extracted, or bound by various contact lens materials.
Methods:
Comfilcon A, balafilcon A, omafilcon A, and etafilcon A were soaked in 500 and 100 pg/mL of interleukin-8 (IL-8), matrix metalloproteinase-9 (MMP-9), or interleukin-1 receptor antagonist (IL-1Ra), and also in combined solutions of inflammatory mediators (500 pg/mL or 100 pg/mL) separately. Lenses were then extracted in 1:1 2% trifluoroacetic acid:acetonitrile. The extracted and residual concentrations of inflammatory mediators were determined using enzyme-linked immunosorbent assays. Absorbed (control-residual) and firmly bound (absorbed-extracted) concentrations were calculated for analysis.
Results:
More MMP-9 was absorbed by omafilcon A (466±9 pg/mL) than balafilcon A (P=0.006; 437±11 pg/mL) or etafilcon A (P=0.001; 428±13 pg/mL) when soaked in 500 pg/mL, but no differences in 100 pg/mL. More MMP-9 remained firmly bound to omafilcon A (P=0.03; 174±3 pg/mL), comfilcon A (P=0.049; 168±34 pg/mL), and balafilcon A (P=0.01; 186±14 pg/mL) than etafilcon A (128±22 pg/mL). There were no differences in IL-8 absorption between lenses; however, more IL-8 remained firmly bound to omafilcon A (P=0.01; 336±25 pg/mL) than etafilcon A (106±133 pg/mL) when soaked in 500 pg/mL. No differences were found in concentrations of absorbed or firmly bound IL-1Ra between materials. When the mediators were combined, IL-8 was absorbed more in etafilcon A (P=0.03) than in other lens materials, but the absorbed IL-8 did not remain firmly bound.
Conclusions:
The uptake and extraction of inflammatory mediators from contact lenses was affected by competitive binding between the mediators.
More Related Videos
08:54Human In-Vivo Bioassay for the Tissue-Specific Measurement of Nociceptive and Inflammatory Mediators
Published on: December 1, 2008
11:54Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
Published on: January 21, 2018
Related Concept Videos
Drug Absorption Mechanism: Carrier-Mediated Membrane Transport
Facilitated diffusion is a passive process that utilizes human Solute Carrier (SLC) transporters. These transporters bind to the drug, undergo structural...
Drug Absorption: Factors Affecting GI Absorption
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Inflammatory Response
Inflammation can be triggered by various stimuli, such as impact, abrasion, chemical irritation, infections, and extreme hot or cold temperatures. These can damage cells and connective tissue fibers,...
Inflammatory Response II: Inflammatory Exudate and Tissue Repair
The typical wound exudate is odorless, transparent, straw-colored, thin, and watery. Exudate, however, can differ depending on the state of wound healing. Likewise, the...