Measurement of murine kidney functional biomarkers using DCE-MRI: A multi-slice TRICKS technique and semi-automated
Kai Jiang1, Hui Tang1, Prasanna K Mishra2
1Division of Nephrology and Hypertension, Mayo Clinic, Rochester, MN, USA.
Purpose:
To propose a rapid multi-slice T1 measurement method using time-resolved imaging of contrast kinetics (TRICKS) and a semi-automated image processing algorithm for comprehensive assessment murine kidney function using dynamic contrast-enhanced MRI (DCE-MRI).
Methods:
A multi-slice TRICKS sampling scheme was implemented in an established rapid T1 measurement method. A semi-automated image-processing scheme employing basic image processing techniques and machine learning was developed to facilitate image analysis. Reliability of the multi-slice technique in measuring renal perfusion and glomerular filtration rate (GFR) was tested in normal mice (n = 7 for both techniques) by comparing to the validated single-slice technique. Utility of this method was demonstrated on mice after either sham surgery (n = 7) or induction of unilateral renal artery stenosis (RAS, n = 8). Renal functional parameters were extracted using a validated bi-compartment model.
Results:
The TRICKS sampling scheme achieved an acceleration factor of 2.7, allowing imaging of eight axial slices at 1.23 s/scan. With the aid of the semi-automated scheme, image analysis required under 15-min for both kidneys per mouse. The multi-slice technique yielded renal perfusion and GFR values comparable to the single-slice technique. Model-fitted renal parameters successfully differentiated control and stenotic mouse kidneys, including renal perfusion (706.5 ± 164.0 vs. 375.9 ± 277.9 mL/100 g/min, P = 0.002), blood flow (1.6 ± 0.4 vs. 0.7 ± 0.7 mL/min, P < 0.001), and GFR (142.9 ± 17.9 vs. 58.0 ± 42.8 μL/min, P < 0.001).
Conclusion:
The multi-slice TRICKS-based DCE-MRI technique, with a semi-automated image processing scheme, allows rapid and comprehensive measurement of murine kidney function.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Kidney Structure
Trial and Error and Algorithm
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Multi-input and Multi-variable systems
In the absence of...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...