Purpose:
To compare image quality and radiation doses for chest DECT acquired with dual-source and rapid-kV switching techniques.
Materials And Methods:
Our institutional Review Board approved retrospective study included 97 patients (54 men, 43 women; 63 ± 14 years) who underwent contrast-enhanced chest DECT with both single source, rapid kV-switching (SS-DECT) and dual source (DS-DECT) techniques per standard of care departmental protocols. Reconstructed images from both scanners had identical section thickness and section interval for virtual monoenergetic and material decomposition iodine (MDI) images. Two thoracic radiologists independently evaluated all DECT for findings, quality of images, perfusion defects (MDI), and presence of artifacts. Radiation dose descriptor, size-specific dose estimates (SSDE), was recorded. Data were analyzed with Wilcoxon Signed Rank and Cohen's Kappa tests.
Results:
There were no significant differences in patient weight or SSDE for the two DECT techniques (p > 0.06). Both radiologists reported no difference in lesion and artifact evaluation on the virtual monoenergetic images from either technique (p > 0.05). However, SS-DECT (in 63-71/97 patients) had substantial artifactual heterogeneity in pulmonary perfusion on MDI images compared to none on DS-DECT (p < 0.001).
Conclusion:
Despite identical patients and associated radiation doses, there were substantial differences in material decomposition iodine images generated from SS-DECT and DS-DECT techniques. Pulmonary heterogeneity on MDI images from SS-DECT leads to artifactual areas of low perfusion and can confound interpretation of true pulmonary perfusion.
Related Concept Videos
Dual Nature of Electromagnetic (EM) Radiation
Wavelength is the distance between two consecutive peaks (the highest point) or troughs (the lowest point) in the wave. Frequency is the number of...
Sources of Self-Esteem III: Social Comparison
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Biological Effects of Radiation
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History: