Outcome of rhinoplasty in patients undergoing autospreader flaps without notable dorsal hump reduction: A clinical trial
Related Experiment Video
Updated: Jan 20, 2026

In Silico Clinical Trials for Cardiovascular Disease
Published on: May 27, 2022
Amir A Sazgar1, Nargess Razmara2, Ali Razfar3
1Otorhinolaryngology Research Center, Tehran University of Medical Sciences, Tehran, Iran; Department of Otolaryngology, Head and Neck Surgery, Vali-Asr Hospital, Imam Khomeini Medical Complex, Tehran University of Medical Sciences, Dr. Gharib Avenue, Keshavarz, Boulevard, Tehran, Iran.
Background:
Reconstruction of the nasal midvault is an important component of successful rhinoplasty outcomes. Use of the autospreader flap is a beneficial technique for preserving the middle vault. In the present study, we evaluated the esthetic and functional outcomes of this technique in patients without notable dorsal hump reduction.
Methodology:
A nonrandomized clinical trial was performed from December 2017 to April 2018 with a minimum follow-up time of 6 months. From among patients seeking rhinoplasty, 38 were eligible for inclusion in the study. The autospreader flap was used to recreate the middle vault in patients undergoing open rhinoplasty, with up to 2 mm bony and cartilaginous dorsal hump removal. Preoperative and postoperative standard photographs were obtained. Assessment of patients was based on Rhinoplasty Outcome Evaluation (ROE) and Nasal Obstruction Symptom Evaluation Scale (NOSE) scores. Objective assessment included quantitative analysis of anthropometric angles, mean dorsal width, nasal length, and projection which was performed on standard pre- and postoperative photos.
Results:
Overall, the patients had statistically significant improvement in their postoperative NOSE scores (9 vs. 6.92, p = 0.0001). The majority of patients were satisfied with the postoperative appearance of their noses. The mean nasal dorsal width (NDW) decreased postoperatively (43% vs. 36%). No difference was found between the mean height of the nose and projection pre- and postoperatively. There was a significant postoperative increase in the nasolabial angle and reduction in nasal length.
Conclusions:
The autospreader flap is an effective technique for preservation and restoration of the middle vault and dorsal esthetic line in cases of less than 2 mm dorsal hump reduction. Nasal function can be improved while achieving good cosmetic outcomes.
More Related Videos
05:16Characterizing Exon Skipping Efficiency in DMD Patient Samples in Clinical Trials of Antisense Oligonucleotides
Published on: May 7, 2020
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Oxidation-Reduction Reactions
Trial and Error and Algorithm
Predicting Reaction Outcomes