Related Experiment Video
Updated: Jan 20, 2026

Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
Published on: October 27, 2020
Micro-Computed Tomography (Micro-CT) Evaluation of Effects of Different Rotary Glide Path Techniques on Canal
Gabrielė Česaitienė1, Tadas Venskutonis1, Vita Mačiulskienė1
1Department of Dental and Oral Pathology, Lithuanian University of Health Sciences, Kaunas, Lithuania.
Abstract:
BACKGROUND The aim of this study was to evaluate the ability of different rotary glide path techniques to maintain canal anatomy by comparing canal transportation and centring abilities in curved root canals using X-ray micro-computed tomography (micro-CT). MATERIAL AND METHODS We selected 36 root canals and randomly assigned them to 3 groups. The first group was instrumented using Pathfile (PF) 1 and PF2, the second group using PF2, and the third group using a Proglider (PG) instrument. Selected tooth samples were scanned using a micro-CT system with 8-µm resolution. Centring ability and transportation were compared at 5 levels: 0.5 mm (A0) and 1 mm (A1) from apical foramen, at the point of maximum root curvature (C0), at 1 mm below it (C-), and 1 mm above it (C+). Area, ratio of areas (RA), perimeter, centroid shift, mean diameter, and ratio of diameter ratios (RDR) were assessed. RESULTS In all groups, there were no significant differences between different levels in all parameters (p>0.05). In group 1, the centroid shift was greatest at A0 and C-, and the least impact was at C0. In group 2, the biggest impacts were at C- and A0, and the smallest at C+. In group 3, the greatest impacts were at A0 and A1, and the smallest at C0. CONCLUSIONS All 3 instrument groups performed very similarly, without significant differences in canal-shaping parameters. Overall, using just PF2 instead of PF 1 and 2 created very similar shaping results, which could reduce the number of instruments needed and the cost of treatment.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Mean free path and Mean free time
Path Between Thermodynamics States
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...