Respiratory motion correction for liver contrast-enhanced ultrasound by automatic selection of a reference image
Ji Zhang1, Yanrong Zhang2,3, Juan Chen2
1Department of Radiology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, 430071, People's Republic of China.
Purpose:
Respiratory motion correction is necessary for the quantitative analysis of liver contrast-enhanced ultrasound (CEUS) image sequences. Most respiratory motion correction methods are based on the dual mode of CEUS image sequences, including contrast and grayscale image sequences. Due to free-breathing motion, the acquired two-dimensional (2D) ultrasound cine might show the in-plane and out-of-plane motion of tumors. The registration of an entire 2D ultrasound contrast image sequence based on out-of-plane images is ineffective. For the respiratory motion correction of CEUS sequences, the reference image is usually considered the standard for the deletion of any out-of-plane images. Most methods used for the selection of the reference image are subjective in nature. Here, a quantitative selection method for an optimal reference image from CEUS image sequences in the B mode and contrast mode was explored.
Methods:
The original high-dimensional ultrasound grayscale image data were mapped into a two-dimensional space using Laplacian Eigenmaps (LE), and K-means clustering was adopted. The center image of the larger cluster with a near-peak contrast intensity was considered the optimal ultrasound reference image. In the ultrasound grayscale image sequence, the images with the maximum correlations to the reference image in the same time interval were selected as the corrected image sequence. The effectiveness of this proposed method was then validated on 18 CEUS cases of VX2 tumors in rabbit livers.
Results:
Correction smoothed the time-intensity curves (TICs) extracted from the region of interest of the CEUS image sequences. Before correction, the average of the total mean structural similarity (TMSSIM) and the average of the mean correlation coefficient (MCC) from the image sequences were 0.45 ± 0.11 and 0.67 ± 0.16, respectively, and after correction, the average TMSSIM and MCC increased (P < 0.001) by 31% to 0.59 ± 0.11 and by 21% to 0.81 ± 0.11, respectively. The average deviation value (DV) index of the TICs from the image sequences prior to correction was 92.16 ± 18.12, and correction reduced the average to 31.71 ± 7.31. The average TMSSIM and MCC values after correction using the mean frame of the reference image (MBMFRI) were clearly lower than those after correction using the proposed method (P < 0.001). Moreover, the average DV after correction using the MBMFRI was obviously higher than that after correction using the proposed method (P < 0.001).
Conclusions:
The breathing frequency of rabbits is notably faster than that of human beings, but the proposed correction method could reduce the effect of the respiratory motion in the CEUS image sequences. The reference image was selected quantitatively, which could improve the accuracy of the quantitative analysis of rabbit liver CEUS sequences using the reference image method based on the current standard of manual selection and the MBMFRI. This easy-to-operate method can potentially be used in both animal studies and clinical applications.
Related Concept Videos
Automatic Processing and Automatic Social Behavior
Distance Corrections
Power Factor Correction
Inertial Frames of Reference
Non-inertial Frames of Reference
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...