Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Replicating Human Osteosarcoma Progression in Immunodeficient Mice for Cancer Study
Published on: March 22, 2024
Intravoxel incoherent motion (IVIM) for response assessment in patients with osteosarcoma undergoing neoadjuvant
Esha Baidya Kayal1, Devasenathipathy Kandasamy2, Kedar Khare3
1Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India.
Purpose:
To explore the role of quantitative Intravoxel incoherent motion (IVIM) parameters and their histogram analysis in characterizing changes in Osteosarcoma receiving neoadjuvant chemotherapy (NACT) and evaluating therapeutic response.
Methods:
Forty patients (N = 40; Male:Female = 30:10; Age = 17.7 ± 5.9years; Metastatic:localized = 17:23) with histologically confirmed Osteosarcoma treated with 3-cycles of NACT were analyzed prospectively. All patients underwent Diffusion weighted imaging (DWI) with 11 b-values (0-800 s/mm2) using 1.5 T MRI scanner at pre-treatment (t0), after 1-cycle (t1) and after 3-cycles (t2) of NACT. Non-invasive response evaluation of NACT was performed using RECIST1.1 criteria. Apparent-diffusion-coefficient (ADC) and IVIM parameters - Diffusion-coefficient (D), Perfusion-coefficient (D*) & Perfusion-fraction (f) and their relative percentage changes from time-point t0-t1 (Δ2) and t0-t2 (Δ2) were evaluated and histogram analysis was performed at three time-points and compared with respect to RECIST1.1 scores.
Results:
Using RECIST1.1 criteria, 11 (27.5%), 21 (52.5%) and 8 (20%) patients were in Partial-responder (PR), Stable-disease (SD) and Progressive-disease (PD) groups respectively. Pre-NACT (t0), average ADC, D,D*&f in tumor volume were 1.36 ± 0.33 × 10-3 mm2/s, 1.3 ± 0.3 × 10-3 mm2/s, 28.44 ± 10.34 × 10-3 mm2/s & 13.95 ± 2.83% respectively. Using ANOVA test, during NACT (t1, t2), D*-variance (p = 0.038, 0.003) and f-skewness (p = 0.03, 0.03) and at t2, D*-entropy (p = 0.001) and f-entropy (p = 0.002) and their Δ2 changes (p = 0.001, 0.003) were statistically significant among response groups. At t1, D*-variance and f-skewness jointly showed AUC = 0.77 & 0.74 in classifying PR (Sensitivity = 73%; Specificity = 70%) and SD (Sensitivity = 74; Specificity = 75%) groups respectively in patient cohort. Δ1 & Δ2 changes of D*-mean, D*-variance, D*-entropy and f-entropy correlated well (0.5-0.6) with tumor-diameter and tumor-volume changes.
Conclusions:
Quantitative IVIM parameters, especially D* &f and their histogram analysis were informative and can be used as noninvasive surrogate markers for early response assessment during the course of NACT in Osteosarcoma.
Related Concept Videos
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Chemotherapy-Induced Nausea and Vomiting: Cannabinoids
Two synthetic agonists of THC,...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Equation of Motion: General Plane motion - Problem Solving
The friction between the roller and the ground is characterized by two coefficients. The static friction coefficient is 0.15, while the kinetic friction coefficient is 0.1. These values are crucial in understanding the interaction between...
Projectile Motion: Example
When we speak of the range (R) of a projectile on...
Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data...

