Cone beam-computed tomography angiography by intravenous contrast injection is reliable to evaluate patients with
Nobuaki Yamamoto1, Yuki Yamamoto1, Izumi Yamaguchi2
1Department of Clinical Neurosciences, Institute of Medical Biosciences, Tokushima University, Tokushima, Japan.
Purpose:
Mechanical thrombectomy (MT) for acute ischemic stroke (AIS) patients due to emergent large vessel occlusion (ELVO) is standard treatment, the benefits, however, are highly time-sensitive. After patient eligibility for reperfusion therapy is determined by conventional radiological examinations, the time to be transferred from the department of radiological examination to angiography-suites is critical. We speculated that the time required for the diagnosis of AIS might be reduced if we could determine MT eligibility in patients with ELVO at angiography-suites. Modern angiography-suites with flat panel detectors can perform cone beam (CB)-CT. We performed CB-CTA using intravenous injection of contrast agent to evaluate occlusion sites, collateral score, and construction of vessels distal to occlusion sites and determined if CB-CTA could be useful to evaluate patients with ELVO.
Methods:
We included 15 patients with ELVO diagnosed by conventional MRI or CT/CTA, and investigated whether CB-CTA was reliable to diagnose occlusion sites. We also studied if collateral score on CB-CTA was associated with prognosis after successful reperfusion by MT by comparison between favorable (modified Rankin scale (mRS) 0-2), and unfavorable outcome group (mRS 3-6).
Results:
There was strong agreement of occlusion sites between CB-CTA and conventional radiological examination (κ = 0.80). Collateral score determined by CB-CTA was significantly different between favorable outcome and unfavorable outcome group (median collateral score 2.3 v.s. 1.3, p = 0.040).
Conclusions:
Although prospective study of AIS patients at a radiography department is indispensable, CB-CTA performed in an angiography-suite might be useful to evaluate patients with ELVO.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Reliability and Validity
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...