A high-strength biodegradable thermoset polymer for internal fixation bone screws: Preparation, in vitro and in vivo
Mingle Cai1, Haoming Liu1, Yuqing Jiang1
1Advanced Biomaterials and Tissue Engineering Center, Huazhong University of Science and Technology, Wuhan 430074, PR China; Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan 430074, PR China.
Abstract:
Thermoset polymers synthesized from the polycondensation of glycerol with biocompatible diacids represent a promising class of absorbable materials for biomedical applications. However, the utility of these polymers for bone fixation devices is hampered due to the lack of mechanical strength. Herein we synthesized a high-strength thermoset polymer, poly(glycerol-succinate) (PGS), via a catalyst-free and solvent-free reaction. The bending strength of PGS reaches 122.01 ± 8.82 MPa, signifying its great potential for fixation devices. The degradation property of the polymer can be tuned by adjusting the monomer ratio and reaction time. Bone screws based on the PGS polymer were successfully manufactured using a lathe. In vitro evaluation showed the PGS polymer was able to well support cell adhesion and proliferation. In vivo evaluation using a rat subcutaneous implantation model showed that the inflammatory response to the polymer was mild. After the PGS screws were implanted in the rabbit femoral condyle for 12 weeks, micro-computed tomography (micro-CT) and histological analysis revealed that the screws achieved good osseointegration. Consequently, the polymer developed in current study can serve as internal fixation devices due to the proper mechanical strength, excellent biocompatibility, and feasibility of manufacturing screws.
More Related Videos
05:57A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Related Concept Videos
Polymers
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Internal Energy
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Internal Receptors