Feasibility of two-dimensional ultrasound shear wave elastography of human fetal lungs and liver: A pilot study
N Mottet1, C Cochet2, C Vidal3
1Department of Obstetrics and Gynecology, Pôle Mère-Femme, University Hospital of Besançon, University of Franche-Comte, 25000 Besançon, France; Nanomedicine Lab, Imagery and Therapeutics, EA4662, University of Franche-Comte, 25000 Besançon, France.
Purpose:
The first aim was to evaluate feasibility and reproducibility of 2-dimensional ultrasound (2D) shear wave elastography (SWE) of human fetal lungs and liver between 24 and 34weeks of gestation. The second aim was to model fetal lung-to-liver elastography ratio (LLE ratio) and to assess its variations according to gestational age and maternal administration of corticosteroids.
Material And Methods:
2D-SWE examinations were prospectively performed in fetuses of women with an uncomplicated pregnancy (group 1) and fetuses of women with a threatened preterm labor requiring administration of corticosteroids (group 2). Two 2D-SWE examinations were performed at "day 0" and "day 2" in group 1; before and 24hours after a course of corticosteroid in group 2. Three operators performed 2 cycles of 3 measurements on the lung (regions A1, A2, A3) and the liver (regions IV, V, VI). Repeatability and reproducibility of measurements were calculated. The fetal LLE ratio was modeled from the most reproducible regions.
Results:
Fifty-five women were enrolled in group 1 and 48 in group 2. For the lung, 8.6% of measurements were considered invalid and 6.9% for the liver. The most reproducible region for the lung was A3 [ICC between 0.70 (95% CI: 0.42-0.85) and 0.78 (95% CI: 0.48-0.90)] and region VI for the liver [ICC between 0.70 (95% CI: 0.40-0.85) and 0.84 (95% CI: 0.60-0.94)]. According to gestational age, a moderate positive linear correlation was found for stiffness values of A3 (R=0.56), V (R=0.46) and VI (R=0.44). LLE ratio values at "day 0" were not different between the two groups but decreased at "day 2" in group 2 (0.2; 95% CI: 0.07-0.34; P<0.001).
Conclusion:
Quantitative fetal lung and liver stiffness measurements are possible with 2D-SWE with acceptable reproducibility.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
14:19Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Related Concept Videos
Pilot and Numeric Relaying
The Wave Nature of Light
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Lung Capacity