A fast volumetric 4D-MRI with sub-second frame rate for abdominal motion monitoring and characterization in MRI-guided radiotherapy
Related Experiment Video
Updated: Jan 20, 2026

MRI-guided dmPFC-rTMS as a Treatment for Treatment-resistant Major Depressive Disorder
Published on: August 11, 2015
Jing Yuan1, Oi Lei Wong1, Yihang Zhou1
1Medical Physics and Research Department, Hong Kong Sanatorium & Hospital, Hong Kong, China.
Background:
To propose a fast volumetric 4D-MRI based on 3D pulse sequence acquisition for abdominal motion monitoring and characterization in MRI-guided radiotherapy (MRgRT).
Methods:
A 3D spoiled gradient echo sequence volumetric interpolated breath-hold examination (VIBE) [repetition time/echo time (TR/TE) =0.53/1.57 ms, flip-angle =5°, receiver bandwidth (RBW) =1,400 Hz/voxel] based 4D-MRI acquisition, accelerated by 4-fold controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), named CAIPIRINHA-VIBE 4D-MRI, was implemented on a 1.5T MRI simulator (MR-sim) and applied for abdominal imaging of nine healthy volunteers under free breathing. One hundred and forty-four dynamics of the entire abdomen volume (56 slices), in total 8,064 (144×56) images with a voxel size of 2.7×2.7×4.0 mm3, were acquired in 89 s for 4D-MRI. This CAIPIRINHA-VIBE 4D-MRI was qualitatively compared with a 2D half-Fourier acquisition single-shot turbo spin-echo (2D-HASTE) based 4D-MRI. The motions of liver dome, kidney and spleen were analyzed using the CAIPIRINHA-VIBE 4D-MRI data. The kidney motion was quantitatively characterized in terms of motion range and the correlations between left and right kidneys.
Results:
CAIPIRINHA-VIBE 4D-MRI was successfully conducted in all subjects. CAIPIRINHA-VIBE 4D-MRI exhibited much higher effective volumetric temporal resolution (0.615 vs. ~5 s/volume) and better reconstructed volume consistency than 2D-HASTE 4D-MRI. CAIPIRINHA-VIBE 4D-MRI was able to characterize the respiratory motion of abdominal organs simultaneously in three orthogonal directions, and could potentially be used for whole abdomen deformable motion tracking. Renal motion range was most pronounced in superior-inferior (SI) direction (L: 10.03±2.65 mm; R: 10.38±2.80 mm), significantly larger (P<0.001) than that in anterior-posterior (AP) and the least in left-right (LR) directions. Right kidney had significantly larger mobility (4.18±2.19 vs. 2.32±1.34 mm, P=0.045) than left kidney in AP, but not in LR and SI directions. The Pearson correlation coefficients r between left and right kidney motion were 0.5063 (P=0.164), 0.6624 (P=0.052) and 0.5752 (P=0.105) in LR, AP and SI correspondingly. The correlation of renal motion in SI and AP was found significant in right kidney (r=0.843, P=0.004) but not in left kidney (r=0.467, P=0.205).
Conclusions:
A fast volumetric 4D-MRI was implemented for abdominal motion monitoring in MRgRT. A sub-second volumetric temporal resolution of 0.615 s, covering the entire abdomen, was demonstrated for respiratory motion monitoring and characterization. This technique holds potentials for MRgRT applications.
More Related Videos
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Framing Effects
Frames
Frames are versatile and widely used in various applications such as structural supports for beams and columns, automobile chassis construction, and in the construction...
Frames: Problem Solving I
Frames: Problem Solving II