Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Morphometric analysis of vidian canal and its relations with surrounding anatomic structures by using cone-beam
M H Kurt1, P Bozkurt2, B Bilecenoğlu3
1Departement of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Emniyet Mahallesi, 06560 Ankara, Turkey.
Background:
We identified the vidian canal (VC) in a Turkish subpopulation on cone-beam computed tomography (CBCT) images and explored its anatomic relationships; the canal serves as an anatomic pathway during endonasal surgical approaches.
Materials And Methods:
Coronal and axial CBCT images of 100 patients (50 males and 50 females) were evaluated (slice thickness and interval, 0.5 mm). We measured the length of the VC length, extent of VC pneumatisation into the sphenoid sinus, position of the VC relative to the medial pterygopalatine plate (MPP), pterygopalatine fossa (PPF) depth, and VC-VC, VC-MPP, and VC-foramen rotundum (FR) distances, the angle between the posterior end of the middle turbinate and the lateral part of the VC anterior opening, and the angle between the VC and the palatovaginal canal.
Results:
The mean VC length was 13.09 ± 2.07 and 13.01 ± 2.12 mm on the right and left sides, respectively. Relative to the MPP, the VC was located medially in 54.5% of patients, on the same level in 36%, and laterally in 9.5%. Pneumatisation was of grade I in 24% of patients, grade II in 33%, grade III in 23.5%, and grade IV in 19.5%. The VC-FR and VC-MPP distances were significantly greater on the left side. The angle between the posterior end of the middle turbinate and the lateral part of the anterior VC opening was significantly greater on the right side. The VC-VC distance was significantly greater when the VC lay lateral to the MPP.
Conclusions:
Anatomic characteristics of the VC on CBCT images unique to Turkish populations should be kept in mind during surgery.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Relative Motion Analysis - Acceleration
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...

