Related Experiment Video
Updated: Jan 20, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody
Michael Safaee1, Taemin Oh2, Murat Pekmezci3
1Department of Neurological Surgery, University of California, San Francisco; michael.safaee@ucsf.edu.
Abstract:
Transforaminal lumbar interbody fusion (TLIF) is commonly used for the treatment of spinal stenosis, degenerative disc disease, and spondylolisthesis. Minimally invasive surgery (MIS) approaches have been applied to this technique with an associated decrease in estimated blood loss (EBL), length of hospital stay, and infection rates, while preserving outcomes with traditional open surgery. Previous MIS TLIF techniques involve significant fluoroscopy that subjects the patient, surgeon, and operating room staff to non-trivial levels of radiation exposure, particularly for complex multi-level procedures. We present a technique that utilizes an intraoperative computed tomography (CT) scan to aid in placement of pedicle screws, followed by traditional fluoroscopy for confirmation of cage placement. Patients are positioned in the standard fashion and a reference arc is placed in the posterior superior iliac spine (PSIS) followed by intraoperative CT scan. This allows for image-guidance-based placement of pedicle screws through a one-inch skin incision on each side. Unlike traditional MIS-TLIF that requires significant fluoroscopic imaging during this stage, the operation can now be performed without any additional radiation exposure to the patient or operating room staff. After completion of the facetectomy and discectomy, final TLIF cage placement is confirmed with fluoroscopy. This technique has the potential to decrease operative time and minimize total radiation exposure.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

