Paw-Print Analysis of Contrast-Enhanced Recordings (PrAnCER): A Low-Cost, Open-Access Automated Gait Analysis System
Hayley A Bounds1, Devon L Poeta1, Petra M Klinge2
1Cognitive, Linguistic & Psychological Sciences, Brown University.
Abstract:
Gait analysis is used to quantify changes in motor function in many rodent models of disease. Despite the importance of assessing gait and motor function in many areas of research, the available commercial options have several limitations such as high cost and lack of accessible, open code. To address these issues, we developed PrAnCER, Paw-Print Analysis of Contrast-Enhanced Recordings, for automated quantification of gait. The contrast-enhanced recordings are produced by using a translucent floor that obscures objects not in contact with the surface, effectively isolating the rat's paw prints as it walks. Using these videos, our simple software program reliably measures a variety of spatiotemporal gait parameters. To demonstrate that PrAnCER can accurately detect changes in motor function, we employed a haloperidol model of Parkinson's disease (PD). We tested rats at two doses of haloperidol: high dose (0.30 mg/kg) and low dose (0.15 mg/kg). Haloperidol significantly increased stance duration and hind paw contact area in the low dose condition, as might be expected in a PD model. In the high dose condition, we found a similar increase in contact area but also an unexpected increase in stride length. With further research, we found that this increased stride length is consistent with the bracing-escape phenomenon commonly observed at higher doses of haloperidol. Thus, PrAnCER was able to detect both expected and unexpected changes in rodent gait patterns. Additionally, we confirmed that PrAnCER is consistent and accurate when compared with manual scoring of gait parameters.
Related Concept Videos
Pedigree Analysis
Qualitative Analysis
For instance, group IV...
Data Reporting and Recording
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Attention-Deficit/Hyperactivity Disorder
Diagnostic Criteria and Symptoms
To diagnose ADHD, symptoms must manifest before age 12 and be evident across multiple settings....


