Objective:
To determine whether passage of whole blood through a microaggregate filter by use of a syringe pump would damage canine erythrocytes.
Sample:
Blood samples obtained from 8 healthy client-owned dogs.
Procedures:
Whole blood was passed through a standard microaggregate filter by use of a syringe pump at 3 standard administration rates (12.5, 25, and 50 mL/h). Prefilter and postfilter blood samples were collected at the beginning and end of a simulated transfusion. Variables measured at each time point included erythrocyte osmotic fragility, mean corpuscular fragility, RBC count, hemoglobin concentration, RBC distribution width, and RBC morphology. In-line pressure when blood passed through the microaggregate filter was measured continuously throughout the simulated transfusion. After the simulated transfusion was completed, filters were visually analyzed by use of scanning electron microscopy.
Results:
Regardless of administration rate, there was no significant difference in mean corpuscular fragility, RBC count, hemoglobin concentration, or RBC distribution width between prefilter and postfilter samples. Additionally, there were no differences in in-line pressure during the simulated transfusion among administration rates. Echinocytes were the erythrocyte morphological abnormality most commonly observed at the end of the transfusion at administration rates of 12.5 and 25 mL/h.
Conclusions And Clinical Relevance:
Results suggested that regardless of the administration rate, the microaggregate filter did not alter fragility of canine RBCs, but may have altered the morphology. It appeared that the microaggregate filter would not contribute to substantial RBC damage for transfusions performed with a syringe pump.
More Related Videos
Related Concept Videos
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Assessing Blood pressure in the Leg
Preparation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: