Pulsatile sterile abscess in the left breast following transapical transcatheter aortic valve implantation: a case
Habib R Khan1,2, Mohammad I Ansari1, Richard W Varcoe1
1Trent Cardiac Centre, Nottingham University Hospitals, City Hospital Campus, Hucknall Road, Nottingham NG51PB, UK.
Background:
Over the last decade, transcatheter treatment of degenerative aortic valve stenosis has been established as an alternative to surgical aortic valve replacement. Late complications of transcatheter treatment of aortic stenosis (AS) are infrequent.
Case Summary:
We report an 87-year-old woman treated successfully with 23 mm Sapien 3 transapical transcatheter aortic valve implantation for severe AS. She presented 4 months later with a pulsatile mass in the left breast. After exclusion of other diagnoses, the mass was attributed to a sterile abscess communicating with the pericardial cavity due to post-operative chest infection and pleural effusion. Multimodality imaging helped to define the anatomy of the abscess and the mechanism of the pulsation.
Discussion:
This is the first report of a pulsatile sterile abscess occurring as a complication of transapical aortic valve implantation. Multimodality imaging confirmed that the pulsation was due to extension of the abscess into the pericardial cavity, excluded direct communication with the left ventricle, and facilitated successful non-surgical management.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process: