Background:
The assessment of exercise self-efficacy in patients with cardiovascular disease (CVD) is necessary to conduct tailored interventions. The aim of the current study was to validate the Iranian version of the Cardiac Exercise Self-efficacy Scale (CESE) for patients with CVD.
Methods:
To develop the Iranian version of the CESE scale, a forward and back translation procedure was followed. Data were collected from 260 patients with CVD who were admitted to Imam Ali Cardiovascular Hospital, Iran, using convenience sampling. Psychometric properties of the scale including validity (face and content validity, discriminant, concurrent, convergent, divergent, and construct validity) and reliability (internal consistency, and test-retest reliability) were assessed. SPSS software was used for statistical analysis.
Results:
The questionnaire had a good face and content validity and reliability, with Cronbach's alpha of 0.87 and intraclass correlation coefficient (ICC) of 0.42. The questionnaire discriminated well between subgroups according to their medical conditions and the "health transition" item in the Short-Form Health Survey (SF-36). There was a significant correlation between CESE and the physical components of the SF-36 (P < 0.001). In addition, a strong to moderate significant correlation was found between the CESE and the Exercise Self-efficacy Scale (ESES) (r = 0.77; P < 0.01) and between CESE and the Hospital Anxiety and Depression Scale (HADS) total (r = -0.45; P < 0.001). The exploratory factor analysis (EFA) identified a four-factor structure model, explaining 71.02% of the observed variance.
Conclusion:
The Persian version of the CESE is a valid and reliable instrument for the evaluation of CVD patients' exercise self-efficacy level in performing regular exercise behaviors.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
10:39Qualitative and Quantitative Validation of Tools with Rating Scales Aimed at Assessing the Quality of University Service-Learning
Published on: August 29, 2025
Related Concept Videos
Reliability and Validity
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Self-Efficacy
pH Scale
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Distribution Reliability and Automation