Related Experiment Video
Updated: Jan 20, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
A randomized clinical study to evaluate the effect of denture adhesive application technique on food particle
Mounir Atassi1, Kimberly R Milleman2, Gary R Burnett1
1GSK Consumer Healthcare Weybridge, Surrey UK.
Abstract:
Food ingress under dentures is a common problem that may be reduced by denture adhesive use. The objective of this study was to explore the effect of the mode of application of a denture adhesive on reducing accumulation of food particles under dentures. This was a single-centre, controlled, single-blind, randomized, three-treatment, three-period, crossover study in participants with complete, removable well-fitting, well-made upper/lower dentures. Treatments were: 1) experimental denture adhesive application (test adhesive) applied with a precision applicator as continuous strips; 2) marketed denture adhesive (positive control) applied using a flat ribbon nozzle as dabs; 3) no adhesive. Food-occlusion testing was performed by assessing peanut particle migration under dentures with denture retention/stability evaluated using the Kapur Index (Olshan modification). Differences were assessed using an ANOVA model. Adhesive oozing and perceptions of the adhesives were assessed by questionnaire. All 83 randomized participants completed the study. There were no significant differences between positive control or test adhesives versus no adhesive, or between test adhesive and positive control, for mass of peanut particles recovered from dentures. Both adhesives had significantly higher retention and stability scores compared with no adhesive (all P < .01). Participants reported significantly higher scores for denture comfort, confidence, satisfaction and movement with both adhesives versus no adhesive (all P < .01). No differences in adhesive ooze were reported between adhesives. No adverse events were reported. In conclusion, there was no difference in performance, as measured by peanut particle mass recovered from upper/lower dentures, for the test adhesive, positive control and no adhesive.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Clinical Applications of Epidermal Stem Cells
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Random Error

