Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
A carbon dioxide monitor that does not show the waveform has value
1Department of Anesthesiology, School of Medicine, University of Louisville, KY 40292.
Abstract:
The author argues that a simple analog needle display can provide the anesthesiologist with the essential information he or she needs when monitoring carbon dioxide in the patient airway. He argues that essentially the most important information is virtually a binary, or all or none, phenomenon; in other words, carbon dioxide is either continuously present in the breathing circuit or is absent. Thus, circuit disconnects and undesirable endotracheal tube locations are readily identified. He relates the analog display of information to that of an automobile speedometer or the hands of a standard wrist watch. The author also compares analog meters with those used by pilots in aviation. He concludes with the argument that the carbon dioxide analyzer provides necessary information without the need to resort to expensive microprocessed displays that would include the waveform and trending, but would substantially increase the cost of the instrument.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Amperometry: Overview
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...