Influence of Corneal Topographic Parameters in the Decentration of Orthokeratology
Tianpu Gu1, Boteng Gong, Daqian Lu
1Center of Optometry (T.G., B.G., D.L., W.L., N.L., Q.H., and R.W.), Tianjin Medical University Eye Hospital, Tianjin, China; Tianjin Medical University Eye Institute (T.G., B.G., D.L., Q.H., and R.W.), Tianjin, China; The School of Optometry & Ophthalmology (T.G., B.G., D.L., W.L., N.L., Q.H., and R.W.), Tianjin Medical University, Tianjin, China.
Objective:
To investigate the lens decentration (LD) of orthokeratology (ortho-k) and the association between pretreatment corneal topographic parameters and LD of the ortho-k.
Methods:
Fifty right eyes of 50 myopes wearing ortho-k lenses were included in the prospective study. Corneal topography was conducted pretreatment to get topographic corneal parameters, including flat-K (K1); steep-K (K2); corneal astigmatism (CA), CA at 0 to 3 mm (3 mm-CA), 3 to 5 mm (5 mm-CA), 5 to 7 mm (7 mm-CA); surface asymmetry index (SAI); surface regularity index; the curvature of best-fit sphere; the diameter of cornea (DC); the distance from the corneal center to the corneal vertex (CCCV); flat eccentricity (E1), steep eccentricity (E2), and E1/E2 (E ratio); and the corneal curvature differences between the nasal and temporal quadrants at 0 to 3 mm (3 mm-Knt), and the corneal curvature differences between the superior and inferior quadrants at 0 to 3 mm (3 mm-Ksi), 5 mm-Knt (at 3-5 mm), 5 mm-Ksi (at 3-5 mm), 7 mm-Knt (at 5-7 mm), and 7 mm-Ksi (at 5-7 mm). The relationship between these cornea topographic parameters and LD of the ortho-k was tested using stepwise multiple linear regression models.
Results:
The mean magnitude of LD was 0.51±0.23 mm (0.06-1.03 mm). According to the stepwise analysis, 4 factors were associated with the overall LD (P<0.01): SAI (β=0.252), CCCV (β=0.539), 5 mm-CA (β=-0.268), and 3 mm-Ksi (β=-0.374); 5 factors were associated with the horizontal LD (P<0.01): DC (β=0.205), CCCV (β=0.881), 3 mm-CA (β=-0.217), 5 mm-Knt (β=0.15), and 3 mm-Ksi (β=-0.18); and 3 factors were associated with the vertical LD (P<0.01): SAI (β=0.542), 5 mm-CA (β=-0.188), and 3 mm-Ksi (β=-0.213).
Conclusion:
Lens decentration is most common, but in most cases, the amount of LD is moderate and acceptable. The magnitude of LD can be predetermined by topographic corneal parameters. Surface asymmetry index, CCCV, 5 mm-Knt, and 3 mm-Ksi may be more preferable parameters in terms of the assessment of LD of ortho-k.
Related Concept Videos
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Factors Influencing Drug Absorption: Anatomical Parameters
Factors Influencing Drug Absorption: Physicochemical Parameters
Enhanced drug absorption can be achieved by reducing particle sizes and increasing surface areas, thereby facilitating...
Topographic Surveying and Contours
Plotting of Topographic Maps
Wave Parameters