Related Experiment Video
Updated: Jan 20, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Whole-Body Computed Tomography Using Low-Dose Biphasic Injection Protocol With Adaptive Statistical Iterative
Ali H Elmokadem1,2, Enas A Ibrahim2,3, Walaa A Gouda2,4
1From the Department of Radiology, Mansoura University, Dakahlia, Egypt.
Aim:
This study aimed to evaluate potential dose savings on a revised protocol for whole-body computed tomography and image quality after implementing Adaptive Statistical Iterative Reconstruction V (ASiR-V) algorism for trauma patients and compare it with routine protocol.
Materials And Methods:
One hundred trauma patients were classified into 2 groups using 2 different scanning protocols. Group A (n = 50; age, 32.48 ± 8.09 years) underwent routine 3-phase protocol. Group B (n = 50; age, 35.94 ± 13.57 years) underwent biphasic injection protocol including unenhanced scan for the brain and cervical spines, followed by a 1-step acquisition of the thorax, abdomen, and pelvis. The ASiR-V level was kept at 50% for all examinations, and then studies were reconstructed at 0% ASiR-V level. Radiation dose, total acquisition time, and image count were compared between groups (A and B). Two radiologists independently graded image quality and artifacts between both groups and 2 ASiR-V levels (0 and 50%).
Results:
The mean (±SD) dose-length product value for postcontrast scans in group A was 1602.3 ± 271.8 mGy · cm and higher when compared with group B (P < 0.001), which was 951.1 ± 359.6 mGy · cm. Biphasic injection protocol gave a dose reduction of 40.4% and reduced the total acquisition time by 11.4% and image count by 37.6%. There was no statistically significant difference between the image quality scores for both groups; however, group A scored higher grades (4.62 ± 0.56 and 4.56 ± 0.67). Similarly, the image quality scores for both ASiR-V levels in both groups were not significantly different.
Conclusions:
Biphasic computed tomography protocol reduced radiation dose with maintenance of diagnostic accuracy and image quality after implementing ASiR-V algorism.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
11:13Assessment of Viability of Human Fat Injection into Nude Mice with Micro-Computed Tomography
Published on: January 7, 2015
Related Concept Videos
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Drug Accumulation During Multiple Dosing: Repetitive IV Injections