Marginal and internal fit of CAD/CAM frameworks in multiple implant-supported restorations: Scanning and milling
Agurne Uribarri1, Eneritz Bilbao-Uriarte1, Aiora Segurola1
1Department of Stomatology II, School of Medicine and Dentistry, University of Basque Country, Leioa, Spain.
Background:
Despite computer-aided design and computer-aided manufacturing (CAD/CAM) technology improving prosthesis fit, errors inherent to digital workflow still exist.
Purpose:
To measure scanning/milling errors, and identify factors influencing marginal (MD) and internal discrepancy (ID).
Materials And Methods:
After scanning, 22 conical abutments in 5 master casts, 6 suprastructures with more than 2 implants (3, 4, and 6) were CAD designed. Angular deviation and errors in the vertical/horizontal planes were analyzed using a coordinate measuring machine (CMM). CAD suprastructures were milled and MD/ID evaluated with micro-computed tomography (CT) and optic microscopy (OM) at one screw test (OST) and final fit test (FFT).
Results:
Mean scanning errors, at the vertical/horizontal planes, and angulation error were 3 μm ± 13, 44 μm ± 34, 0.3° ± 0.2°, respectively. Angulation errors nearly double in structures >3 abutments (0.26°vs 0.4°). OM MD in FFT/OST was 57.7 μm ± 13.9/100.7 μm ± 34.6, respectively. Micro-CT FFT-MD was 38.9 μm ± 12.8. Lineal/perimetral ID was 49.6 μm ± 11.9 and 108.2° ± 41.8, respectively. Structures >3-implants were 2.3 times more likely to present higher MD (CI95%:0.4-13.6). Nearly all the internal horizontal gap was due to scanning errors (44 of 49.6 μm). Horizontal scanning errors were three times more likely to present greater ID (CI95%:0.5-17.4).
Conclusion:
Horizontal plane scanning errors are greater than vertical errors. Scanning angulation/milling errors are higher for suprastructures>3implants. Scanning/milling errors are associated with ID/MD, respectively, leading to micro-gap formation. A CMM reduces scanning errors in >3-implant-frameworks before milling the final piece.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
08:10Precision Milling of Carbon Nanotube Forests Using Low Pressure Scanning Electron Microscopy
Published on: February 5, 2017
Related Concept Videos
Margin of Error
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Restorative Care
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error