Related Experiment Video
Updated: Jan 20, 2026

Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
Published on: January 18, 2020
Determination of febuxostat in human plasma by high performance liquid chromatography (HPLC) with
Bishoy Kamel1, Kenneth M Williams2, Garry G Graham2
1St Vincent's Clinical School, University of New South Wales Sydney, Australia; Department of Clinical Pharmacology and Toxicology, St Vincent's Hospital, Sydney, New South Wales, Australia.
Abstract:
Febuxostat prevents gout attacks by lowering serum urate. Aspects of the pharmacokinetic-pharmacodynamic relationship of febuxostat concentrations to urate in gout patients need further elucidation. In order to undertake these studies, the assay methodology for febuxostat has been enhanced and validated to meet FDA standards. An HPLC method with fluorescence-detection has been modified to increase sensitivity, reduce complexity, shorten the sample preparation process and improve the inter-day coefficient of variation of the lowest quality control sample (0.03 μg/L). Protein in plasma samples (200 μL) is now precipitated with acetonitrile (400 μL) containing the internal standard (2-naphthoic acid). The supernatant is analysed at excitation and emission wavelengths of 320 and 380 nm, respectively as in the previous method. A Luna C18 column (Phenomenex, Australia) at 40 °C with mobile phase of glacial acetic acid (0.032%) in acetonitrile:water (60:40, v:v), an injection volume of 10 μL and a flow rate of 1.5 mL/min is employed. Analysis time is 8 min. Calibration curves in drug-free plasma range from 0.005 to 10.00 μg/mL. Data points are fitted using linear regression with a weighting factor of 1/concentration. The inter-day accuracy and imprecision of the quality control samples (0.0075, 0.015, 3.00 and 9.80 μg/mL) is 90-115% and ≤ 14.5%, respectively.
More Related Videos
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography HPLC
Published on: March 15, 2017
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Affinity Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...