Related Experiment Video
Updated: Jan 20, 2026

Label-free Isolation and Enrichment of Cells Through Contactless Dielectrophoresis
Published on: September 3, 2013
Multi-Biometric System Based on Cutting-Edge Equipment for Experimental Contactless Verification
Lukas Kolda1, Ondrej Krejcar2, Ali Selamat1,3,4,5
1Faculty of Informatics and Management, University of Hradec Kralove, Hradec Kralove 50003, Czech Republic.
Abstract:
Biometric verification methods have gained significant popularity in recent times, which has brought about their extensive usage. In light of theoretical evidence surrounding the development of biometric verification, we proposed an experimental multi-biometric system for laboratory testing. First, the proposed system was designed such that it was able to identify and verify a user through the hand contour, and blood flow (blood stream) at the upper part of the hand. Next, we detailed the hard and software solutions for the system. A total of 40 subjects agreed to be a part of data generation team, which produced 280 hand images. The core of this paper lies in evaluating individual metrics, which are functions of frequency comparison of the double type faults with the EER (Equal Error Rate) values. The lowest value was measured for the case of the modified Hausdorff distance metric - Maximally Helicity Violating (MHV). Furthermore, for the verified biometric characteristics (Hamming distance and MHV), appropriate and suitable metrics have been proposed and experimented to optimize system precision. Thus, the EER value for the designed multi-biometric system in the context of this work was found to be 5%, which proves that metrics consolidation increases the precision of the multi-biometric system. Algorithms used for the proposed multi-biometric device shows that the individual metrics exhibit significant accuracy but perform better on consolidation, with a few shortcomings.
More Related Videos
10:21Author Spotlight: Exploring the Role of Inflammation in the Co-occurrence of Primary Sjogren's Syndrome and Lung Adenocarcinoma
Published on: September 20, 2024
13:09Rat Liver Perfusion and Primary Hepatocytes Isolation: An Old Procedure Crucial for Cutting-Edge 3D Organoids Culture
Published on: November 22, 2024
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Strategies of Self-Presentation II: Self-Verification
Leveling Equipment
Personal Protective Equipment
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...