Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3
Xiaofei Yu1,2, Yadong Yu3,4, Xinzhong Shao1,2
1Department of Hand Surgery, The Third Hospital of Hebei Medical University, NO.139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Purpose:
This study aimed to compare the radiographic and functional results of Arbeitsgemeinschaftfür Osteosynthesefragen (AO) type C2/C3 fracture of distal radius between volar locking plate (VLP) and external fixation (EF).
Methods:
It was a retrospective comparative study. Between January 2015 and March 2018, a total of 62/117 patients who underwent EF (23) or VLP fixation (39) for AO type C2/C3 distal radius fractures were assessed. The follow-up period was at least 12 months. Gartland-Werley scale and the disabilities of the arm, shoulder, and hand (DASH) scale were used to evaluate the overall functional outcomes; wrist range of motion and grip strength were measured. The radiographic parameters included radial inclination, volar tilt, radial length, ulnar variance, and articular step-off. All of the comparisons were performed using SPSS 21.0.
Results:
The mean follow-up time was 17.1 months. At final visit, VLP performed better in wrist flexion (69.7° vs 62.3°, p < 0.001), forearm pronation (73.1° vs 64.8°, p = 0.027) and supination (70.6° vs 63.1°, p = 0.033) than EF, but not different with regard to other kinematic parameters. No significant difference was found between two groups, in term of Gartland-Werley or DASH score (p > 0.05). The ulnar variance and articular step-off was significantly more improved in VLP than EF group, being 0.6 vs 1.6 mm (p = 0.002) and 0.5 vs 1.2 mm (p = 0.007). The overall rate of complications did not differ in both groups (28.2% vs 34.5%) (p = 0.587).
Conclusions:
Compared to EF, VLP fixation showed better performance in wrist mobility, correction of ulnar variance, and improving articular congruence, but with the comparable overall functional outcomes and complication rate.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Conjugate Addition of Enolates: Michael Addition
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Additional Subnuclear Structures
The nucleus contains many membrane-less subnuclear organelles or nuclear bodies, such as nucleoli, Cajal bodies, speckles,...