Related Experiment Video
Updated: Jan 20, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
A novel adjustable locking plate (ALP) for segmental bone fracture treatment
Omer Subasi1, Atacan Oral1, Ismail Lazoglu1
1Manufacturing and Automation Research Center, Koc University, Istanbul 34450, Turkey.
Abstract:
A novel Ti6Al4V adjustable locking plate (ALP) is designed to provide enhanced bone stability for segmental bone fractures and to allow precise positioning of disconnected segments. The design incorporates an adjustable rack and pinion mechanism to perform compression, distraction and segment transfer during plate fixation surgery. The aim of this study is to introduce the advantages of the added feature and computationally characterize the biomechanical performance of the proposed design. Structural strength of the novel plate is analyzed using numerical methods for 4-point bending and fatigue properties, following ASTM standards. An additional mechanical failure finite element test is also conducted on the rack and pinion to reveal how much torque can be safely applied to the mechanism by the surgeon. Simulation results predict that the new design is sufficiently strong to not fail under regular anatomical loading scenarios with close bending strength and fatigue life properties to clinically used locking compression plates. The novel ALP design is expected to be a good candidate for addressing problems regarding fixation of multi-fragmentary bone fractures.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Adjusting a Traverse
The Anchoring-and-Adjustment Heuristic
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment