Related Experiment Video
Updated: Jan 20, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Fully threaded headless compression screw versus partially threaded cancellous lag screw in medial malleolus
Tugrul Bulut1, Merve Gursoy2, Hakan Ertem3
1Department of Orthopaedics and Traumatology, Ataturk Training and Research Hospital, Izmir Katip Celebi University, Basin Sitesi, 35360, Izmir, Turkey. drtugrulbulut@yahoo.com.
Purpose:
The aim of this study was to evaluate the clinical and radiological results of medial malleolar fractures, which were treated with fully threaded headless compression screws and to compare the clinical and radiological results of this screws and partially threaded cancellous lag screws.
Methods:
Sixty-one patients who attended the final follow-up examination were included in the study. Group 1 comprised 29 patients applied with fully threaded headless compression screws and Group 2 comprised 32 patients with partially threaded cancellous lag screws. Radiological evaluation was made with standard radiographs. The clinical evaluations were applied using the AOFAS ankle hindfoot scale. Pain or sensitivity by touching over the medial malleolus was recorded and scored according to Visual Analog Scale.
Results:
No significant differences were determined between the groups with respect to age, gender, fracture type, follow-up time, bone union time and AOFAS scores. The medial sensitivity associated with implant irritation was significantly lower in Group 1. There was no need for removal of the fixation material in any patient of Group 1.
Conclusions:
The results of this study showed satisfactory results in the two fixation techniques in medial malleolar fractures. However, the rates of medial sensitivity associated with implant irritation were lower in the group where fully threaded headless compression screws were used. Therefore, to prevent postoperative patient dissatisfaction caused by persistent medial sensitivity associated with implant irritation, despite successful surgical treatment, the primary choice may be fully threaded headless compression screws.
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Lagging Strand Synthesis
There are several major differences between synthesis of the leading strand and synthesis of the lagging strand. 1) Leading strand synthesis happens in the direction of replication fork opening, whereas lagging strand synthesis happens in the...
Lagging Strand Synthesis
Radiological Investigation I: X-ray and CT