Osteosynthesis of sternal fractures with double locking compression plate fixation: a retrospective cohort study
Nina Kalberer1, Herman Frima2, Christian Michelitsch1
1Department of Trauma Surgery, Kantonsspital Graubünden, Loëstrasse 170, 7000, Chur, Switzerland.
Purpose:
Sternal fractures are rare injuries and mostly treated non-operatively. In selected cases, internal fixation becomes necessary. No standard operative approach has been determined yet among experts. The aim of this study is to describe our treatment algorithm and results after operative stabilisation of sternal fractures with locking compression plates (LCP), mainly focusing on the functional outcome.
Methods:
A retrospective cohort study was conducted. We included all patients after operative stabilisation of a sternal fracture between 2008 and 2016. Endpoints were the functional outcome using the Activities of Daily Living (ADL) score, pain analysed by the numeric rating scale (NRS), breathing ability, complications and implant removal.
Results:
Eighteen out of 153 (12%) patients with a sternal fracture underwent operation. Three patients were lost to follow-up. Eleven out of 15 (73%) patients were treated with double straight LCP 3.5 mm implants and 4 (27%) patients with pre-countered LCP 3.5 mm implants. Mean follow-up was 57 months. The median ADL score was 1 (1-4), the median NRS was 0 (0-9), and respiratory complaints scored a median of 1 (1-4). No non-union, hardware failure or implant-related complication occurred. Post-operative complications were pneumonia (20%) and respiratory insufficiency (20%). Implants were removed in 4/15 (27%) patients; three times due to implant-related irritation, once on patient's request.
Conclusion:
Operative stabilisation of sternal fractures with double LCP 3.5 mm provides excellent long-term functional results and seems to be an appropriate option for internal fixation. The rate of post-operative complications is low; however, 27% had a second operation for implant removal.
More Related Videos
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Fixing Double-strand Breaks