Comparison of technical failure of MR elastography for measuring liver stiffness between gradient-recalled echo and
Dong Wook Kim1, So Yeon Kim1, Hee Mang Yoon1
1The Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
Background:
Magnetic resonance elastography (MRE) using a gradient-recalled echo (GRE) or a recently available spin-echo echo-planar imaging (SE-EPI) sequence is a promising noninvasive method for measuring liver stiffness. However, it sometimes fails to measure stiffness values, thereby resulting in technical failures.
Purpose:
To assess and compare technical failures of MRE for measuring liver stiffness between GRE and SE-EPI sequences.
Study Type:
Systematic review and meta-analysis.
Population:
Eight studies with both GRE and SE-EPI, 22 studies with only GRE, one study with only SE-EPI.
Field Strength/Sequence:
Either 1.5 or 3T MRE using GRE and/or SE-EPI.
Assessment:
Through an Ovid-MEDLINE and EMBASE database search, original articles investigating the proportion of MRE technical failures in the measurement of liver stiffness published up until October 2018 were screened and selected.
Statistical Analysis:
The pooled proportions of technical failures under GRE and SE-EPI were calculated using random-effects meta-analysis of single proportions and inverse variance for calculating weights. Subgroup analyses were performed to explore the covariates affecting heterogeneity. Head-to-head comparisons of technical failure between the sequences were conducted with eight MRE studies using both GRE and SE-EPI.
Results:
The pooled proportion of technical failure under GRE MRE was 5.8% (95% confidence interval [CI], 4.6-7.4%), and a subgroup analysis showed higher technical failure rates at 3T than at 1.5T. The pooled proportion of technical failure under SE-EPI MRE was 2.0% (95% CI, 1.3-3.4%), without significant differences (P = 0.38-0.89) being observed in the subgroup analyses. In the eight studies comparing the two sequences, failure was more frequently observed with GRE than with SE-EPI (9.4% vs. 1.9%; P < 0.01).
Data Conclusion:
MRE conducted with SE-EPI sequences showed a lower technical failure rate than GRE sequences. With GRE sequences, a magnetic field of 3T was associated with higher technical failure rates than was 1.5T.
Level Of Evidence:
1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;51:1086-1102.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...