Control Volume Analysis for Mass Conservation and Calibration of a Flow Passage
Published on: April 30, 2023
Effect of Inlet Air Volumetric Flow Rate on the Performance of a Two-Stage Cyclone Separator
Jihe Chen1, Zhong-An Jiang1, Jushi Chen1
1School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China.
Abstract:
It is very important to improve the cyclone separator separation efficiency for fine particles. On the basis of the Reynolds stress model (RSM), a new two-stage cyclone separation device is modeled and the model is simulated under six kinds of air volumetric flow rate conditions. The two-stage cyclone separator was then tested in the laboratory and the experimental data were compared with the simulation data. The results show that the RSM model can predict the performance of the two-stage cyclone separation device with high accuracy. Increasing of the air volumetric flow rate can not only improve the separation efficiency of the two-stage cyclone separator, but also effectively change the classification range. Because of the centrifugal force, even if the pressure drop is low, the 1st-cyclone can completely separate particles above 5.0 μm. When the air volumetric flow rate is more than 290 m3/h, the 2nd-cyclone can effectively separate the particles below 2.0 μm. The study also confirmed the nonlinear relationship between the pressure drop and the cut-off particle size and the maximum particle size. When the pressure drop exceeds a certain value, there is no longer any effect on the cut-off particle size and the maximum particle size.
More Related Videos
Related Concept Videos
Mass Conservation and Flow Rate Measurements
The purpose of this experiment is to demonstrate the calibration of a flow passage as a flowmeter using a control volume (CV) formulation [1, 2]. The CV analysis focuses on the macroscopic effect of flow on engineering systems, rather than the detailed description that could be achieved with a detailed differential analysis. These two techniques should be...
05:20Separation of Plasmodium falciparum Late Stage-infected Erythrocytes by Magnetic Means
09:56Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
06:39A High Performance Impedance-based Platform for Evaporation Rate Detection
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns