PROSPECTIVE STUDY FOR VALIDATION OF A SINGLE PROTOCOL FOR THE 13C-UREA BREATH TEST USING TWO DIFFERENT DEVICES IN THE DIAGNOSIS OF H. PYLORI INFECTION
Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Detection and Treatment of Helicobacter pylori Infection
Published on: July 28, 2023
Luiz Gonzaga Vaz Coelho1, Osmar Reni Trindade1, Laiane Alves Leão1
1Universidade Federal de Minas Gerais, Instituto Alfa de Gastroenterologia do Hospital das Clínicas, Belo Horizonte, MG, Brasil.
Background:
13C-urea breath test (UBT) is the gold-standard, noninvasive method for H. pylori diagnosis. However, there is no uniform standardization of the test. This situation can be unpractical for laboratories running with two or more devices.
Objective:
To perform a prospective comparison validation study of UBT employing one validated protocol for two different devices: BreathID Hp Lab System® (Exalenz Bioscience Ltd, Israel), here called device A and IRIS-Doc2® (Wagner Analysen-Technik, Germany, now Mayoly Spindler Group, France), here called device B, in the diagnosis of H. pylori infection.
Methods:
A total of 518 consecutive patients (365 females, 153 males, mean age 53 years) referred for UBT were included. All patients received device A protocol as follow: after at least one hour fasting, patients filled two bags prior to the test, then ingested an aqueous solution containing 75 mg of 13C-urea with a 4.0 g citric acid powder and filled another two bags 15 min after ingesting the test solution. One pair of breath sample bags (before and after ingestion) was analyzed by the two different devices. A delta over baseline (DOB) ≥5‰ indicated H. pylori infection. Statistics: Wilcoxon test, kappa coefficient with 95% CI, Wilson's method.
Results:
Considering the device A protocol as the gold standard, its comparison with device B showed a sensitivity of 99.3% (95% CI: 96.3-99.9) and a specificity of 98.9% (95% CI: 97.3-99.6). Kappa coefficient was 0.976 (95% IC: 0.956-0.997).
Conclusion:
Correlation between the two devices was excellent and supports a uniform standardization of UBT.
Related Concept Videos
06:40Quantitative Polymerase Chain Reaction (qPCR)-Based Rapid Diagnosis of Helicobacter pylori Infection and Antibiotic Resistance
04:56Detection of Helicobacter pylori Infection and Antibiotic Resistance via Stool Quantitative Polymerase Chain Reaction Analysis
02:49Quantification of Helicobacter pylori Load in an Infected Mouse Stomach
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Prospect Theory