The Pneumatron: An automated pneumatic apparatus for estimating xylem vulnerability to embolism at high temporal

Luciano Pereira1,2, Paulo R L Bittencourt3,4, Vinícius S Pacheco4

  • 1Laboratory of Plant Physiology "Coaracy M. Franco", Center R&D in Ecophysiology and Biophysics, Agronomic Institute (IAC), Campinas, Brazil.

Related Concept Videos

¹H NMR of Labile Protons: Temporal Resolution01:10

¹H NMR of Labile Protons: Temporal Resolution

Protons bonded to heteroatoms such as nitrogen and oxygen exhibit a range of chemical shift values. This is due to the varying degree of hydrogen bonding between the proton and the heteroatom in other molecules. The extent of hydrogen bonding affects the electron density around the proton, thereby giving different chemical shift values for the protons in the proton NMR spectrum.
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
1.7K
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
1.3K
Registration of Calcium Transients in Mouse Neuromuscular Junction with High Temporal Resolution using Confocal Microscopy11:12

Registration of Calcium Transients in Mouse Neuromuscular Junction with High Temporal Resolution using Confocal Microscopy

The protocol describes the method of loading a fluorescent calcium dye through the cut nerve into mouse motor nerve terminals. In addition, a unique method for recording fast calcium transients in the peripheral nerve endings using confocal microscopy is...
2.4K
Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx07:14

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx

Previous work suggests that the nitrogen isotopic composition of atmospheric nitrogen oxides might distinguish the influence of different sources in the environment. We report on an automated, mobile, field-based method for the high collection efficiency of atmospheric NOx for N isotopic analysis at an hourly time...
12.1K
Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET09:03

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET

This manuscript describes two radiotracer administration protocols for FDG-PET (constant infusion and bolus plus infusion) and compares them to bolus administration. Temporal resolutions of 16 s are achievable using these...
10.8K
Xylem Water Distribution in Woody Plants Visualized with a Cryo-scanning Electron Microscope10:47

Xylem Water Distribution in Woody Plants Visualized with a Cryo-scanning Electron Microscope

Observing the water distribution within the xylem provides significant information regarding water flow dynamics in woody plants. In this study, we demonstrate the practical approach to observe xylem water distribution in situ by using a cryostat and cryo-SEM, which eliminates artifactual changes in the water status during sample...
9.2K