Related Experiment Video
Updated: Jan 20, 2026

Subcutaneous Infection of Methicillin Resistant Staphylococcus Aureus MRSA
Published on: February 9, 2011
Pilot Evaluation of a Fully Automated Bioinformatics System for Analysis of Methicillin-Resistant Staphylococcus
Nicholas M Brown1, Beth Blane2, Kathy E Raven3
1Clinical Microbiology and Public Health Laboratory, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
Abstract:
Genomic surveillance that combines bacterial sequencing and epidemiological information will become the gold standard for outbreak detection, but its clinical translation is hampered by the lack of automated interpretation tools. We performed a prospective pilot study to evaluate the analysis of methicillin-resistant Staphylococcus aureus (MRSA) genomes using the Next Gen Diagnostics (NGD) automated bioinformatics system. Seventeen unselected MRSA-positive patients were identified in a clinical microbiology laboratory in England over a period of 2 weeks in 2018, and 1 MRSA isolate per case was sequenced on the Illumina MiniSeq instrument. The NGD system automatically activated after sequencing and processed fastq folders to determine species, multilocus sequence type, the presence of a mec gene, antibiotic susceptibility predictions, and genetic relatedness based on mapping to a reference MRSA genome and detection of pairwise core genome single-nucleotide polymorphisms. The NGD system required 90 s per sample to automatically analyze data from each run, the results of which were automatically displayed. The same data were independently analyzed using a research-based approach. There was full concordance between the two analysis methods regarding species (S. aureus), detection of mecA, sequence type assignment, and detection of genetic determinants of resistance. Both analysis methods identified two MRSA clusters based on relatedness, one of which contained 3 cases that were involved in an outbreak linked to a clinic and ward associated with diabetic patient care. We conclude that, in this pilot study, the NGD system provided rapid and accurate data that could support infection control practices.
Related Concept Videos
12:18Subcutaneous Infection of Methicillin Resistant Staphylococcus Aureus (MRSA)
09:03Multiplex PCR Assay for Typing of Staphylococcal Cassette Chromosome Mec Types I to V in Methicillin-resistant Staphylococcus aureus
14:04Biosensor for Detection of Antibiotic Resistant Staphylococcus Bacteria
07:32Evaluating the Immune Response of a Nanoemulsion Adjuvant Vaccine Against Methicillin-Resistant Staphylococcus aureus (MRSA) Infection
08:32Development and Assessment of Intracellular Infection Models for Staphylococcus aureus
03:35In Vitro Biofilm Synthesis by Staphylococcus aureus

