Feasibility study of using one-tenth mSv radiation dose in young children chest CT with 80 kVp and model-based
Jihang Sun1, Qifeng Zhang1, Di Hu1
1Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No.56, Nanlishi Road, Xicheng District, Beijing, 100045, China.
Abstract:
CT has become a routine imaging modality based on its excellent ability of displaying lung structures and diseases. But, how to reduce radiation dose of routine CT examination is a concern for radiologists. Our study aimed to evaluate the feasibility of using 80kVp and a model-based iterative reconstruction (MBIR) algorithm to achieve one-tenth mSv dose chest CT in infants and young children. Thirty-two cases (study group, average age 1.71 ± 1.01 years) underwent non-contrast chest CT examination at low dose with 80 kV, 4mAs and was reconstructed with MBIR (LD-MBIR) and the standard adaptive statistical iterative reconstruction (ASIR) algorithm (LD-ASIR); another group (control group) of 32 children underwent routine-dose chest CT with 100 kV and was reconstructed with ASIR only (RD-ASIR). The subjective and objective image quality of the three groups were measured and statistically compared. The radiation dose for the low dose scan was 0.09 ± 0.02 mSv, 6% of the routine dose. All LD-MBIR images were diagnostically acceptable. Compared with the RD-ASIR images, the LD-MBIR images were similar in noise in the left ventricle, muscles, lung field, on-par in displaying large airways, lung lucency and mediastinum, but were inferior in displaying lung marking, small airways and mediastinum. Thus, MBIR images with low dose in pediatric chest CT can be used in the diagnosis for lung field and air way disorders in infants and young children.
Related Concept Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
08:17Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
12:38Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
08:17Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation


