Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
ForwardFocus with cochlear implant recipients in spatially separated and fluctuating competing signals - introduction
Matthias Hey1, Thomas Hocke2, Britta Böhnke1
1Audiology, ENT Clinic, UKSH, Kiel, Germany.
Abstract:
Objective: To clinically evaluate ForwardFocus in noise with experienced Nucleus® cochlear implant (CI) recipients.Design: Listening performance with ForwardFocus was compared against the best in class directional microphone program (BEAM®). Speech comprehension was tested with the Oldenburg sentence test with competing signals (stationary, three, six and 18-talker babble) in both co-located and spatially-separated listening environments. Additionally, normal hearing participants were tested monaurally in the same listening environments as a reference and to promote cross-study comparisons between CI clinical study outcomes.Study sample: Post-lingually deaf adult CI recipients (n = 20) who were experienced users of the Nucleus sound processor (Cochlear Limited).Results: Improved speech comprehension was found with the ForwardFocus program compared to the BEAM program in a co-located frontal listening environment for both stationary and fluctuating competing signals. In spatially-separated environments ForwardFocus provided significant speech reception threshold (SRT) improvements of 5.8 dB for three-talker competing signals, respectively.Conclusions: ForwardFocus was shown to significantly improve speech comprehension in a wide range of listening environments. This technology is likely to provide significant improvements in real-world listening for CI recipients, given the clinically relevant performance outcomes in challenging dynamic noise environments, bringing their performance closer to their normal hearing peers.
Related Concept Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
08:06Robotic Cochlear Implantation for Direct Cochlear Access
09:56Cochlear Implantation in the Guinea Pig
09:10Performing Intracochlear Electrocochleography During Cochlear Implantation
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
06:54Performing Repeated Intraoperative Impedance Telemetry Measurements during Cochlear Implantation